Findings

CVE-2024-20767

Adobe ColdFusion Improper Access Control Vulnerability

Published Mar 18, 2024 · updated Jun 17, 2026 · adobe coldfusion

ColdFusion versions 2023.6, 2021.12 and earlier are affected by an Improper Access Control vulnerability that could result in arbitrary file system read. An attacker could leverage this vulnerability to access or modify restricted files. Exploitation of this issue does not require user interaction. Exploitation of this issue requires the admin panel be exposed to the internet.

Timeline

Detection, updates, and resolution for this record.

  1. Mar 18, 2024 · Catalog

    Detected

    ColdFusion versions 2023.6, 2021.12 and earlier are affected by an Improper Access Control vulnerability that could result in arbitrary file system read. An attacker could leverage this vulnerability to access or modify restricted files. Exploitation of this issue does not require user interaction. Exploitation of this issue requires the admin panel be exposed to the internet.

  2. Dec 16, 2024 · CISA KEV

    Known exploited

    Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.

  3. Jan 6, 2025 · CISA KEV

    Remediation due

    Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.

  4. Jun 17, 2026 · Catalog

    Updated

    ColdFusion versions 2023.6, 2021.12 and earlier are affected by an Improper Access Control vulnerability that could result in arbitrary file system read. An attacker could leverage this vulnerability to access or modify restricted files. Exploitation of this issue does not require user interaction. Exploitation of this issue requires the admin panel be exposed to the internet.

Required action

Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.

CISA due date Jan 6, 2025

Affected

  • cpe adobe/coldfusion2021
  • vendor Adobe ColdFusionversion unspecified

Sources

  • CISA KEVCVE-2024-20767

    Adobe ColdFusion contains an improper access control vulnerability that could allow an attacker to access or modify restricted files via an internet-exposed admin panel.

    cisa.gov
  • CVE.orgCVE-2024-20767

    Official CVE identifier

    cve.org
  • FIRST EPSSCVE-2024-20767

    30-day exploitation probability 98.5%

    first.org
  • Public archive entry. The exploit body is not stored here.

    exploit-db.com
  • Metasploit Modulesauxiliary_gather/coldfusion_pms_servlet_file_read

    Public module reference (normal). Module source is not copied into this catalog.

    rapid7.com
  • NIST NVDCVE-2024-20767

    ColdFusion versions 2023.6, 2021.12 and earlier are affected by an Improper Access Control vulnerability that could result in arbitrary file system read. An attacker could leverage this vulnerability to access or modify restricted files. Exploitation of this issue does not requir

    nvd.nist.gov

References