Vulnerability · CVE-2026-31963
HTSlib is a library for reading and writing bioinformatics file formats.
Published Mar 18, 2026 · catalog updated Jun 17, 2026 · HTSlib is a library
Check if you run it
No confirmed exploitation is on record for CVE-2026-31963. EPSS is 0.54%. Act only if a listed version of HTSlib is a library is installed.
- Severity
- High8.8
- Known exploitation
- Not in CISA/VulnCheck KEV
- EPSS
- 0.54%
- Remediation
- Advisory link
- Affected products
- cpe htslib/htslib
HTSlib is a library for reading and writing bioinformatics file formats. CRAM is a compressed format which stores DNA sequence alignment data. As one method of removing redundant data, CRAM uses reference-based compression so that instead of storing the full sequence for each alignment record it stores a location in an external reference sequence along with a list of differences to the reference at that location as a sequence of "features". When decoding these features, an out-by-one error in a test for CRAM features that appear beyond the extent of the CRAM record sequence could result in an invalid write of one attacker-controlled byte beyond the end of a heap buffer. Exploiting this bug causes a heap buffer overflow. If a user opens a file crafted to exploit this issue, it could lead to the program crashing, or overwriting of data and heap structures in ways not expected by the program. It may be possible to use this to obtain arbitrary code execution. Versions 1.23.1, 1.22.2 and 1.21.1 include fixes for this issue. There is no workaround for this issue.
Are you affected?
Enter the version you run. The result uses only the ranges stored on this record.
The check returns affected, not affected, or incomplete. It does not guess a version that is missing from the record.
- cpe htslib/htslibversion unspecified
- cpe htslib/htslib1.23
How to fix CVE-2026-31963
Recommended remediation
A patch or advisory reference is linked. Open the original publisher for availability by product version.
Official advisories
What to do
Three questions, each answered from this record only. Confirm the vendor advisory before you patch.
Should you patch?
No confirmed exploitation is on record for CVE-2026-31963. EPSS is 0.54%. Act only if a listed version of HTSlib is a library is installed.
Which versions are affected?
Compare what you have installed with 1.23. Compare the installed version with the linked vendor advisory before you change production.
What should an analyst verify?
CWE-122: Heap-based Buffer Overflow; CWE-129: Improper Validation of Array Index; CWE-787: Out-of-bounds Write. EPSS 0.54%. There is no CISA KEV listing. No Exploit-DB or Metasploit reference is linked. Use the source links for the original advisory.
Code
The project this record applies to. Exploit listings stay in References.
Timeline
Detection, updates, and resolution for this record.
Mar 18, 2026 · NIST NVD
Detected
HTSlib is a library for reading and writing bioinformatics file formats. CRAM is a compressed format which stores DNA sequence alignment data. As one method of removing redundant data, CRAM uses reference-based compression so that instead of storing the full sequence for each alignment record it stores a location in an external reference sequence along with a list of differences to the reference a
Jun 17, 2026 · NIST NVD
Updated
HTSlib is a library for reading and writing bioinformatics file formats. CRAM is a compressed format which stores DNA sequence alignment data. As one method of removing redundant data, CRAM uses reference-based compression so that instead of storing the full sequence for each alignment record it stores a location in an external reference sequence along with a list of differences to the reference a
Sources
- CVE.orgVulnerability recordCVE-2026-31963
Official CVE identifier
cve.org - FIRST EPSSExploitation probabilityCVE-2026-31963
30-day exploitation probability 0.5%
first.org - NIST NVDVulnerability recordCVE-2026-31963
HTSlib is a library for reading and writing bioinformatics file formats. CRAM is a compressed format which stores DNA sequence alignment data. As one method of removing redundant data, CRAM uses reference-based compression so that instead of storing the full sequence for each ali
nvd.nist.gov
References
Freshness
Last verified in this catalog Oct 18, 2026. Significant claims (KEV, EPSS, CVSS, affected ranges) come from the source rows above — open the original publisher for the authoritative advisory.