Vulnerability · CVE-2026-94582
A memory buffer overflow vulnerability exists in the internal diagnostic and route validation routines used by the Fabric Shortest Path First (FSPF) protocol component…
Published Oct 8, 2026 · catalog updated Oct 14, 2026 · fabric operating system
Check if you run it
No confirmed exploitation is on record for CVE-2026-94582. EPSS is 0.14%. Act only if a listed version of fabric operating system is installed.
Gaps on this record
- No version range is stored. A customer cannot check an installed version against this record.
- No vendor fix or required action is stored. Compare the linked advisory before you change production.
- Severity
- Medium6.8
- Known exploitation
- Not in CISA/VulnCheck KEV
- EPSS
- 0.14%
- Remediation
- Advisory link
- Affected products
- cpe broadcom/fabric operating system
A memory buffer overflow vulnerability exists in the internal diagnostic and route validation routines used by the Fabric Shortest Path First (FSPF) protocol component of Brocade Fabric OS versions before 10.0.1. While this code path is part of internal diagnostic functionality and is not directly accessible via standard user interfaces or CLI management commands, an input processing flaw allows incoming or internally routed diagnostic state payloads to exceed allocated memory boundaries. An attacker that is able to chain or link other vulnerabilities to exploit this internal diagnostic could cause a heap- or stack-based memory overrun, resulting in a daemon crash (Denial of Service) or potential arbitrary code execution within the context of the routing daemon.
Are you affected?
Enter the version you run. The result uses only the ranges stored on this record.
The check returns affected, not affected, or incomplete. It does not guess a version that is missing from the record.
- cpe broadcom/fabric operating systemversion unspecified
How to fix CVE-2026-94582
Recommended remediation
A patch or advisory reference is linked. Open the original publisher for availability by product version.
Official advisories
What to do
Three questions, each answered from this record only. Confirm the vendor advisory before you patch.
Should you patch?
No confirmed exploitation is on record for CVE-2026-94582. EPSS is 0.14%. Act only if a listed version of fabric operating system is installed.
Which versions are affected?
Affected version ranges are not on this record. Compare the installed version with the linked vendor advisory before you change production.
What should an analyst verify?
CWE-120: Classic Buffer Overflow. EPSS 0.14%. There is no CISA KEV listing. No Exploit-DB or Metasploit reference is linked. Use the source links for the original advisory.
Code
The project this record applies to. Exploit listings stay in References.
No public source repository is identified for this product.
Timeline
Detection, updates, and resolution for this record.
Oct 8, 2026 · NIST NVD
Detected
A memory buffer overflow vulnerability exists in the internal diagnostic and route validation routines used by the Fabric Shortest Path First (FSPF) protocol component of Brocade Fabric OS versions before 10.0.1. While this code path is part of internal diagnostic functionality and is not directly accessible via standard user interfaces or CLI management commands, an input processing flaw allows i
Oct 14, 2026 · NIST NVD
Updated
A memory buffer overflow vulnerability exists in the internal diagnostic and route validation routines used by the Fabric Shortest Path First (FSPF) protocol component of Brocade Fabric OS versions before 10.0.1. While this code path is part of internal diagnostic functionality and is not directly accessible via standard user interfaces or CLI management commands, an input processing flaw allows i
Sources
- CVE.orgVulnerability recordCVE-2026-94582
Official CVE identifier
cve.org - FIRST EPSSExploitation probabilityCVE-2026-94582
30-day exploitation probability 0.1%
first.org - NIST NVDVulnerability recordCVE-2026-94582
A memory buffer overflow vulnerability exists in the internal diagnostic and route validation routines used by the Fabric Shortest Path First (FSPF) protocol component of Brocade Fabric OS versions before 10.0.1. While this code path is part of internal diagnostic functionality a
nvd.nist.gov
References
Freshness
Last verified in this catalog Oct 18, 2026. Significant claims (KEV, EPSS, CVSS, affected ranges) come from the source rows above — open the original publisher for the authoritative advisory.